Technical Meeting Paper

199607 – Deveney – The Application of Level Crossing Processors on the Newport to Ararat Standard Gauge Line

Downloads are only accessible for registered, logged in, users. Click here to log in.

Level Crossing Processors were chosen for application on the Newport to Ararat section of the standard gauge line due to the requirements of the safeworking system to be employed. The design and operational issues are discussed and then problems related to interference between units encountered is outlined. A mathematical analysis of the interference based on transmission line theory using the properties of the concrete sleeper track is presented. The analysis indicates that a potential exists for interference between level crossing processors of the same frequency over long distances.

Date of paper.

July 19th, 1996

Author Details

Tom Deveney

National Rail Corporation